Affected Unit | Affected Unit EIC Code | Market Participant | Market Participant Code | Message ID | Event Status | Type Of Unavailability | Type Of Event | Publication Date | Event Start | Event Stop | Unit of Measurement | Unavailable Capacity | Available Capacity | Installed Capacity | Reason Of Unavailability | Remarks | Fuel Type | Bidding Zone |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
< 3 4 5 6 7 > | ||||||||||||||||||
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006108_003 | Dismissed | Unplanned | Production unavailability | 2021-06-15T14:54:13+01:00 | 2021-06-11T20:54:00+01:00 | 2021-06-16T07:59:00+01:00 | MW | 61 | 180 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006108_002 | Dismissed | Unplanned | Production unavailability | 2021-06-15T14:51:03+01:00 | 2021-06-11T20:54:00+01:00 | 2021-07-16T07:59:00+01:00 | MW | 61 | 180 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006108_001 | Dismissed | Unplanned | Production unavailability | 2021-06-14T15:01:31+01:00 | 2021-06-11T20:54:00+01:00 | 2021-07-29T09:00:00+01:00 | MW | 61 | 180 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006088_002 | Inactive | Planned | Production unavailability | 2021-06-05T19:01:53+01:00 | 2021-06-03T08:00:00+01:00 | 2021-06-05T18:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006088_001 | Dismissed | Planned | Production unavailability | 2021-06-01T15:26:12+01:00 | 2021-06-03T08:00:00+01:00 | 2021-06-05T18:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006075_002 | Inactive | Unplanned | Production unavailability | 2021-06-01T18:01:53+01:00 | 2021-05-25T11:10:00+01:00 | 2021-06-01T17:00:00+01:00 | MW | 32 | 209 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006075_001 | Dismissed | Unplanned | Production unavailability | 2021-05-25T11:24:51+01:00 | 2021-05-25T11:10:00+01:00 | 2021-06-01T17:00:00+01:00 | MW | 32 | 209 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006047_002 | Inactive | Unplanned | Production unavailability | 2021-05-17T12:01:53+01:00 | 2021-05-17T09:15:00+01:00 | 2021-05-17T11:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Turbine |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000006047_001 | Dismissed | Unplanned | Production unavailability | 2021-05-17T09:46:19+01:00 | 2021-05-17T09:15:00+01:00 | 2021-05-17T11:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Turbine |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005931_004 | Inactive | Unplanned | Production unavailability | 2021-04-02T03:02:31+01:00 | 2021-03-31T17:30:00+01:00 | 2021-04-02T02:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Generator |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005931_003 | Dismissed | Unplanned | Production unavailability | 2021-04-01T17:08:30+01:00 | 2021-03-31T17:30:00+01:00 | 2021-04-02T02:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Generator |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005931_002 | Dismissed | Unplanned | Production unavailability | 2021-03-31T19:42:20+01:00 | 2021-03-31T17:30:00+01:00 | 2021-04-01T17:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Generator |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005931_001 | Dismissed | Unplanned | Production unavailability | 2021-03-29T23:58:26+01:00 | 2021-03-29T23:55:00+01:00 | 2021-04-30T00:00:00+01:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005930_003 | Dismissed | Unplanned | Production unavailability | 2021-03-29T18:45:05+01:00 | 2021-03-26T19:44:00+00:00 | 2021-03-29T19:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Electrical Equipment |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005930_002 | Dismissed | Unplanned | Production unavailability | 2021-03-29T16:46:14+01:00 | 2021-03-26T19:44:00+00:00 | 2021-03-29T19:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Electrical Equipment |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005930_001 | Dismissed | Unplanned | Production unavailability | 2021-03-27T10:34:26+00:00 | 2021-03-26T19:44:00+00:00 | 2021-03-29T17:00:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Electrical Equipment |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005537_002 | Dismissed | Unplanned | Production unavailability | 2021-03-27T10:29:32+00:00 | 2021-02-19T00:00:00+00:00 | 2021-03-27T10:25:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005537_001 | Dismissed | Unplanned | Production unavailability | 2021-02-19T11:06:33+00:00 | 2021-02-19T00:00:00+00:00 | 2021-04-30T17:00:00+01:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005531_002 | Inactive | Unplanned | Production unavailability | 2021-02-10T11:31:54+00:00 | 2021-02-10T08:20:00+00:00 | 2021-02-10T10:20:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Turbine |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005531_001 | Dismissed | Unplanned | Production unavailability | 2021-02-10T08:34:34+00:00 | 2021-02-10T08:20:00+00:00 | 2021-02-10T10:20:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Turbine |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005521_003 | Inactive | Unplanned | Production unavailability | 2021-02-09T04:31:52+00:00 | 2021-02-04T09:00:00+00:00 | 2021-02-09T03:30:00+00:00 | MW | 0 | 241 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005521_002 | Dismissed | Unplanned | Production unavailability | 2021-02-08T21:02:16+00:00 | 2021-02-04T09:00:00+00:00 | 2021-02-09T03:30:00+00:00 | MW | 0 | 241 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005521_001 | Dismissed | Unplanned | Production unavailability | 2021-02-04T10:46:45+00:00 | 2021-02-04T09:00:00+00:00 | 2021-02-10T17:00:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_006 | Dismissed | Unplanned | Production unavailability | 2021-02-04T10:45:07+00:00 | 2020-11-05T17:00:00+00:00 | 2021-02-04T09:00:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_005 | Dismissed | Unplanned | Production unavailability | 2020-12-08T21:43:37+00:00 | 2020-11-05T17:00:00+00:00 | 2021-04-30T00:00:00+01:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_004 | Dismissed | Unplanned | Production unavailability | 2020-11-30T10:07:29+00:00 | 2020-11-05T17:00:00+00:00 | 2020-12-31T17:00:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_003 | Dismissed | Unplanned | Production unavailability | 2020-11-09T16:56:16+00:00 | 2020-11-05T17:00:00+00:00 | 2020-11-30T17:00:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_002 | Dismissed | Unplanned | Production unavailability | 2020-11-07T17:26:42+00:00 | 2020-11-05T17:00:00+00:00 | 2020-11-09T17:00:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005368_001 | Dismissed | Unplanned | Production unavailability | 2020-11-05T19:47:31+00:00 | 2020-11-05T17:00:00+00:00 | 2020-11-07T17:00:00+00:00 | MW | 15 | 226 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005410_002 | Inactive | Unplanned | Production unavailability | 2020-12-08T18:01:53+00:00 | 2020-12-08T11:00:00+00:00 | 2020-12-08T17:00:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005410_001 | Dismissed | Unplanned | Production unavailability | 2020-12-08T12:14:01+00:00 | 2020-12-08T11:00:00+00:00 | 2020-12-08T17:00:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005406_002 | Dismissed | Unplanned | Production unavailability | 2020-12-03T17:32:21+00:00 | 2020-12-03T12:01:00+00:00 | 2020-12-04T00:00:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Fuel Supply |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005406_001 | Dismissed | Unplanned | Production unavailability | 2020-12-03T12:49:27+00:00 | 2020-12-03T12:01:00+00:00 | 2020-12-04T00:00:00+00:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Fuel Supply |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005371_002 | Dismissed | Unplanned | Production unavailability | 2020-11-07T17:26:05+00:00 | 2020-11-07T00:00:00+00:00 | 2020-11-09T17:00:00+00:00 | MW | 14 | 227 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005371_001 | Dismissed | Unplanned | Production unavailability | 2020-11-07T17:24:39+00:00 | 2020-11-07T00:00:00+00:00 | 2020-11-09T17:00:00+00:00 | MW | 14 | 227 | 241 | Failure | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005321_004 | Inactive | Planned | Production unavailability | 2020-10-15T18:01:51+01:00 | 2020-10-09T09:00:00+01:00 | 2020-10-15T17:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005321_003 | Dismissed | Planned | Production unavailability | 2020-10-15T13:56:41+01:00 | 2020-10-09T09:00:00+01:00 | 2020-10-15T17:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005321_002 | Dismissed | Planned | Production unavailability | 2020-10-13T10:04:07+01:00 | 2020-10-09T09:00:00+01:00 | 2020-10-15T13:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005321_001 | Dismissed | Planned | Production unavailability | 2020-10-07T13:13:13+01:00 | 2020-10-09T09:00:00+01:00 | 2020-10-13T17:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Planned Outage |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_007 | Inactive | Unplanned | Production unavailability | 2020-10-14T10:35:02+01:00 | 2020-08-07T10:34:00+01:00 | 2020-10-15T13:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_006 | Dismissed | Unplanned | Production unavailability | 2020-10-13T19:24:19+01:00 | 2020-08-07T10:34:00+01:00 | 2020-10-15T13:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_005 | Dismissed | Unplanned | Production unavailability | 2020-09-29T12:15:00+01:00 | 2020-08-07T10:34:00+01:00 | 2020-10-14T17:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_004 | Dismissed | Unplanned | Production unavailability | 2020-08-27T13:23:23+01:00 | 2020-08-07T10:34:00+01:00 | 2020-09-30T17:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_003 | Dismissed | Unplanned | Production unavailability | 2020-08-20T15:23:48+01:00 | 2020-08-07T10:34:00+01:00 | 2020-09-07T17:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_002 | Dismissed | Unplanned | Production unavailability | 2020-08-18T19:47:31+01:00 | 2020-08-07T10:34:00+01:00 | 2020-08-24T09:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005234_001 | Dismissed | Unplanned | Production unavailability | 2020-08-07T10:36:04+01:00 | 2020-08-07T10:34:00+01:00 | 2020-09-07T17:00:00+01:00 | MW | 50 | 191 | 241 | Foreseen Maintenance | Plant Fault - Boiler |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005281_002 | Dismissed | Unplanned | Production unavailability | 2020-08-26T12:19:00+01:00 | 2020-08-25T17:15:00+01:00 | 2020-08-26T17:15:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Fuel Supply |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005281_001 | Dismissed | Unplanned | Production unavailability | 2020-08-25T17:30:47+01:00 | 2020-08-25T17:15:00+01:00 | 2020-08-26T17:15:00+01:00 | MW | 241 | 0 | 241 | Failure | Plant Fault - Fuel Supply |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005240_002 | Dismissed | Planned | Production unavailability | 2020-08-19T15:38:42+01:00 | 2020-08-24T09:00:00+01:00 | 2020-08-28T17:00:00+01:00 | MW | 0 | 241 | 241 | Foreseen Maintenance | Grid |
Fossil Oil | 10Y1001A1001A59C |
TB3 | 47W0000000000994 | SSE Generation Ireland Ltd |
47X0000000000592 | 0000000000000000000005240_001 | Dismissed | Planned | Production unavailability | 2020-08-13T12:48:36+01:00 | 2020-08-24T09:00:00+01:00 | 2020-08-28T17:00:00+01:00 | MW | 241 | 0 | 241 | Foreseen Maintenance | Grid |
Fossil Oil | 10Y1001A1001A59C |